Podrobný popis
NETSET BOX F/UTP 5e E1517_1 is a top quality cat. 5e outdoor cable (foil-shielded twisted-pair cable) designed for use in professional computer networks outside buildings. The shielding layer made of aluminum foil allows to minimize crosstalk and interference with the external environment. The sheath made of polyethylene (PE) is highly resistant to UV radiation (surface installations) and humidity (ground installations).
Distinguishing features of NETSET BOX F/UTP CAT 5e:
- highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee,
- parameters far exceeding the requirements for Category 5e twisted pair cables confirmed by the tests performed in Telecommunications Equipment Testing Laboratory of the National Institute of Telecommunications in Warsaw, Poland,
- preliminary quality control of materials and thorough tests of the final product,
- solid wires of 0.5 mm diameter (24 AWG),
- wire insulation made of homogeneous, colored PE; outer diameter: 1.0 mm; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
- insulated wires twisted in pairs, all protected with polyester foil,
- shielding layer made of aluminum foil,
- sheath made of black PE of 6.2 mm external diameter,
- meter markers - length error less than 0.5%.
NETSET BOX F/UTP CAT 5e E1517_1 Ethernet cable is manufactured in compliance with EN 50173, ISO/IEC 61156-5 edition:2002, ISO/IEC 11801 standards.
The cable comes with a 15-year warranty.
The manufacturer guarantees stability of cable parameters at least for 15 years, on the condition that the cable is packed, transported, installed, and used according to adequate European standards (among others E-79100 and EN 50174-1), within the permissible environmental conditions.
The NETSET BOX F/UTP CAT 5e E1517_1 cable can be used in a wide temperature range: -20oC...+50oC, and installed between -30oC and +50 oC.
Specifications
Name | NETSET BOX F/UTP 5e |
Code | E1517_1 |
Structure | |
Wires | solid copper conductors Ø 0.50 mm (24 AWG) |
Wire insulation / cable shield | PE, PE foil / aluminum foil |
Sheath | PE (black) |
Outer diameter [mm] | 6,2±0,4 |
Copper content [kg/km] | 14,2 |
Weight [kg/km] | 34,2 |
Electrical parameters | |
Wave impedance [Ω] | 100 ±15 |
Capacitance of any transmission path at 1kHz [nF/km] | ≤56 |
Nominal Velocity of Propagation (NVP) [%] | 67 |
Resistance of any transmission path [Ω/km] | ≤ 188 |
Asymmetry in capacitance of transmission paths to the ground [pF/km] | ≤ 1600 |
Insulation resistance [MΩ/km] | > 5000 |
Installation and operation | |
Operating temperature range [°C] | -20...+50 |
Operating humidity range (RH) [%] | 0...100 |
Installation temperature range [oC] | -30...+50 |
Minimum bending radius (inside buildings) [radius to diameter ratio] | >8 |
NETSET BOX F/FTP CAT 5e cable has been tested by
Telecommunications Equipment Testing Laboratory
of the
National Institute of Telecommunications in Warsaw, Poland
and got
TECHNICAL OPINION OF THE INSTITUTE
The technical opinion of the institute for NETSET BOX F/UTP Cat.5e is available here.
- Pair resistance and resistance asymmetry testing.
Cable | Pair | Wire | Wire resistance [Ω/km] | Resistance asymmetry [%] |
F/UTP cat. 5e | 1 | a | 103,41 | 0,60 |
b | 104,03 | |||
2 | a | 107,32 | 0,66 | |
b | 106,61 | |||
3 | a | 101,85 | 0,77 | |
b | 102,64 | |||
4 | a | 100,66 | 0,39 | |
b | 101,05 | |||
Required | - | - | ≤150 | ≤3,0 |
- Effective capacitance and capacitance asymmetry testing.
Cable | Tor | Effective capacitance [nF/km] | Capacitance asymmetry [pF/km] |
F/UTP cat. 5e | 1 | 45,40 | 13 |
2 | 48,19 | 480 | |
3 | 46,14 | 195 | |
4 | 44,09 | 15 | |
Required | - | - | ≤1600 |
- Insulation testing.
Pair | Wire | Insulation resistance [MΩ/km] | |
F/UTP Cat. 5e | 1 | a | 9,6·104 |
b | 1,2·105 | ||
2 | a | 9,0·104 | |
b | 7,4·104 | ||
3 | a | 1,1·105 | |
b | 8,3·104 | ||
4 | a | 1,7·105 | |
b | 1,3·105 | ||
Required | - | - | ≥150 |
- Tests of electric strength of insulation.
Test method | Test voltage [VAC] | |
Applied (passed) | Required | |
Voltage applied between connected in parallel all a wires and all b wires | 1000 | 1000 |
- End-to-end attenuation testing.
Pair | Effective attenuation [dB] | |
F/UTP Cat. 5e | 1 | 23,1 |
2 | 22,6 | |
3 | 22,1 | |
4 | 21,9 | |
Required | - | ≤24,9 |
- Near End Cross Talk (NEXT) testing.
Cable | Pair-to-pair | NEXT [dB] |
F/UTP cat. 5e | 1 - 2 | 40,9 |
1 - 3 | 42,1 | |
1 - 4 | 41,8 | |
2 - 3 | 42,4 | |
2 - 4 | 40,6 | |
3 - 4 | 43,7 | |
Required | - | ≥34,0 |
- Return loss testing.
Cable | Pair | Return loss [dB] |
F/UTP cat. 5e | 1 | 21,1 |
2 | 22,0 | |
3 | 21,9 | |
4 | 20,6 | |
Required | - | ≥19,4 |
Cable | Pair | PS-NEXT [dB] |
F/UTP cat. 5e | 1 | 36,79 |
2 | 36,42 | |
3 | 37,90 | |
4 | 37,05 | |
Required | - | ≥31,0 |
NETSET BOX F/UTP 5e fulfills all requirements for Category 5e cables, with a large safety margin.
Specifikace
Typ zboží | |||
Výrobce | |||
Značka | NETSET | ||
Typ kabelu | F/UTP | ||
Aplikace | Externí | ||
Category | 5e | ||
Délka kabelu | m | Sold per meter | |
CPR class | FCA | ||
Fyzikální vlastnosti | |||
Žila | Material | Cooper | |
Žila | Průměr | mm | 0,5 |
Izolace vodiče | Material | HDPE (polyethylene) | |
Izolace vodiče | Průměr | mm | 1 |
Kroucené páry | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
Conductor shield | Material | Al/Mylar | |
plášť | Material | LDPE | |
plášť | Průměr | mm | 6,2 |
thickness | mm | 0,55 | |
Barva | RAL9005 (black) | ||
No | |||
Nosný kabel | No | ||
Rip-cord | Ano | ||
Drážkování | No | ||
Chyba tisku značky délky | <0.5 | ||
Elektrické vlastnosti | |||
Impedance | Ω | 100 | |
Rychlost šíření NVP | 67 | ||
Zpoždění zkreslení | ns/100 m | <45 | |
Stejnosměrný odpor | Ohm/100 m | 9,5 | |
Asymetrie odporu | <5 | ||
Ztráty zpětného toku | 1 MHz | ≥dB | 20 |
Ztráty zpětného toku | 4 MHz | ≥dB | 23 |
8 MHz | ≥dB | 24,5 | |
10 MHz | ≥dB | 25 | |
16 MHz | ≥dB | 25 | |
20 MHz | ≥dB | 25 | |
25 MHz | ≥dB | 24,3 | |
31.25 MHz | ≥dB | 23,6 | |
62.5 MHz | ≥dB | 21,5 | |
100 MHz | ≥dB | 20,1 | |
Ztráty | 4 MHz | ≤dB | 4,1 |
8 MHz | ≤dB | 5,8 | |
10 MHz | ≤dB | 6,5 | |
16 MHz | ≤dB | 8,2 | |
20 MHz | ≤dB | 9,3 | |
25 MHz | ≤dB | 10,4 | |
31.25 MHz | ≤dB | 11,7 | |
62.5 MHz | ≤dB | 17 | |
100 MHz | ≤dB | 22 | |
NEXT (přeslech na blízkém konci) | 1 MHz | ≤dB | 65,3 |
NEXT (přeslech na blízkém konci) | 4 MHz | ≤dB | 56,3 |
8 MHz | ≤dB | 51,8 | |
10 MHz | ≤dB | 50,3 | |
16 MHz | ≤dB | 47,2 | |
20 MHz | ≤dB | 45,8 | |
25 MHz | ≤dB | 44,3 | |
31.25 MHz | ≤dB | 42,9 | |
62.5 MHz | ≤dB | 38,4 | |
100 MHz | ≤dB | 35,3 | |
PSNEXT (součet výkonových přeslechů na blízkém konci) | 1 MHz | ≥dB | 62,3 |
PSNEXT (součet výkonových přeslechů na blízkém konci) | 4 MHz | ≥dB | 53,3 |
8 MHz | ≥dB | 48,8 | |
10 MHz | ≥dB | 47,3 | |
16 MHz | ≥dB | 44,4 | |
20 MHz | ≥dB | 42,8 | |
25 MHz | ≥dB | 41,3 | |
31.25 MHz | ≥dB | 39,9 | |
62.5 MHz | ≥dB | 35,4 | |
100 MHz | ≥dB | 32,3 | |
ELFEXT | 1 MHz | ≥dB | 63,8 |
ELFEXT | 4 MHz | ≥dB | 51,8 |
8 MHz | ≥dB | 45,7 | |
10 MHz | ≥dB | 43,8 | |
16 MHz | ≥dB | 39,7 | |
20 MHz | ≥dB | 37,8 | |
25 MHz | ≥dB | 35,8 | |
31.25 MHz | ≥dB | 33,9 | |
62.5 MHz | ≥dB | 27,9 | |
100 MHz | ≥dB | 23,8 | |
PSELFEXT (součet výkonových přeslechů na vzdáleném konci) | 1 MHz | ≥dB | 60,8 |
PSELFEXT (součet výkonových přeslechů na vzdáleném konci) | 4 MHz | ≥dB | 48,8 |
8 MHz | ≥dB | 42,7 | |
10 MHz | ≥dB | 40,8 | |
16 MHz | ≥dB | 36,7 | |
20 MHz | ≥dB | 34,8 | |
25 MHz | ≥dB | 32,8 | |
31.25 MHz | ≥dB | 30,9 | |
62.5 MHz | ≥dB | 24,9 | |
100 MHz | ≥dB | 20,8 | |
Mechanické vlastnosti | |||
Provozní teplota | °C | -20...+70 | |
Teplota pokládky | °C | -30...+50 | |
Minimální poloměr ohybu pro vnitřní instalaci | Průměr | >8 |