A short instructional video on crimping RJ-45 connector on a category 6 UTP cable, according to the EIA/EIA 568B standard. The items used: NETSET U/UTP cat. 6 cable, 8-pin RJ-45 modular plug, modular plug boot, HT-210N crimping tool, cable tester NS-468AT.
Podrobný popis
- High-rise buildings (WW) with a height of more than 55 m above ground level
- High-rise buildings (W) with a height of more than 25 m to 55 m above ground level or residential buildings with the number of floors above ground level from 9 to 18 inclusive
- Buildings in human risk category ZL I with rooms intended for simultaneous presence of more than 50 people who are not permanent users, and not intended primarily for use by people with reduced mobility
- Buildings in human risk category ZL II – intended primarily for use by people with reduced mobility, such as hospitals, nurseries, kindergartens, nursing homes
- Buildings in human risk category ZL III – commercial buildings not classified unser ZL I and ZL II
- Buildings in human risk category ZL IV – residential
- Buildings in human risk category ZL V – collective residence not classified under ZL I and ZL II
- PM and IN buildings (production buildings, warehouses, livestock etc.).
- top quality materials, made to tight specifications, proven with a, 15-year quality guarantee,
- flammability class B2ca-s1a-d1-a1
- preliminary quality control of materials and thorough tests of the finished product,
- meter markers,
- cooper solid wires diameter 0.565 mm,
- insulation of conductors made of insulating, mass-coloured HDPE, conductor diameter: 0.98 mm, insulation colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
- cable sheath made of LSZH compliant material, outer diameter 6.4 mm,
- length marker print error max. 0.5%
EN50575:2014, EN60332-1-2:2004, EN50399:2011, EN60754-2:2014, EN 13501-6:2014.
- Return Loss
Frequency [MHz] | Result (min.) [dB] |
1 | 20.0 |
4 | 23.0 |
8 | 24.5 |
10 | 25.0 |
16 | 25.0 |
20 | 25.0 |
25 | 24.3 |
31.25 | 23.6 |
62.5 | 21.5 |
100 | 20.1 |
200 | 18 |
250 | 17.3 |
- Attenuation
Frequency [MHz] | Result (min.) [dB] |
1 | 2,03 |
4 | 3,78 |
8 | 5,32 |
10 | 5,95 |
16 | 8,47 |
25 | 9,51 |
31,25 | 10,67 |
62,5 | 15,38 |
100 | 19,8 |
200 | 28,98 |
250 | 32,85 |
- NEXT (near end crosstalk)
Frequency [MHz] | Result (min.) [dB] |
1 | 74.3 |
4 | 65.3 |
8 | 60.8 |
10 | 59.3 |
16 | 56.2 |
20 | 54.8 |
25 | 53.3 |
31.25 | 51.9 |
62.5 | 47.7 |
100 | 44.3 |
200 | 39.8 |
250 | 38.3 |
- PSNEXT (power sum near end crosstalk)
Frequency [MHz] | Result (min.) [dB] |
1 | 72,3 |
4 | 63,3 |
8 | 58,8 |
10 | 57,3 |
16 | 54,2 |
20 | 51,3 |
31,25 | 49,9 |
62,5 | 45,4 |
100 | 42,3 |
200 | 37,8 |
250 | 36,3 |
- ELFEXT (equal level far end crosstalk loss testing)
Frequency [MHz] | Result (min.) [dB] |
1 | 67,8 |
4 | 55,8 |
8 | 49,7 |
10 | 47,8 |
16 | 43,7 |
20 | 41,8 |
25 | 39,8 |
31,25 | 37,9 |
62,5 | 31,9 |
100 | 27,8 |
200 | 21,8 |
250 | 19,8 |
- PSELFEXT (power sum equal level far end crosstalk loss testing)
Frequency [MHz] | Result (min.) [dB] |
1 | 64.8 |
4 | 52.8 |
8 | 46.7 |
10 | 44.8 |
16 | 40.7 |
20 | 38.8 |
25 | 36.8 |
31.25 | 34.9 |
62.5 | 28.9 |
100 | 24.8 |
200 | 18.8 |
250 | 16.8 |
Specifikace
Název | NETSET U/UTP cat. 6 | ||
Typ zboží | |||
Výrobce | Dipol | ||
Brand | NETSET | ||
Cable type | U/UTP | ||
Aplikace | |||
Category | 6 | ||
Cable length | m | 500 | |
CPR class | B2ca s1a,d1,a1 | ||
Fyzikální vlastnosti | |||
Žila | Material | Cooper | |
Diameter | mm | ||
Conductor insulation | Material | HDPE (polyethylene) | |
Diameter | mm | ||
Twisted pairs | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
Twisted pair shield | Material | Al/Mylar | |
plášť | Diameter | mm | |
thickness | mm | ||
Barva | RAL7032 (gray) | ||
No | |||
Nosný kabel | No | ||
Rip-cord | Yes | ||
Spline | No | ||
Length marker print error | <0.5 | ||
Elektrické vlastnosti | |||
Impedance | Ω | 100 | |
Delay skew | ns/100 m | <45 | |
Asymetrie kapacity ve vztahu k zemi | pF/100m | 330 | |
DC resistance | Ohm/100 m | ||
Resistance asymmetry | <5 | ||
Return Loss | 1 MHz | ≥dB | 20 |
4 MHz | ≥dB | 23 | |
8 MHz | ≥dB | ||
10 MHz | ≥dB | 25 | |
16 MHz | ≥dB | 25 | |
20 MHz | ≥dB | 25 | |
25 MHz | ≥dB | ||
31.25 MHz | ≥dB | ||
62.5 MHz | ≥dB | ||
100 MHz | ≥dB | ||
200 MHz | ≥dB | 18 | |
250 MHz | ≥dB | ||
Loss | 1 MHz | ≤dB | 2 |
4 MHz | ≤dB | ||
8 MHz | ≤dB | ||
10 MHz | ≤dB | ||
16 MHz | ≤dB | ||
20 MHz | ≤dB | ||
25 MHz | ≤dB | ||
31.25 MHz | ≤dB | ||
62.5 MHz | ≤dB | ||
100 MHz | ≤dB | ||
200 MHz | ≤dB | ||
250 MHz | ≤dB | ||
NEXT (near-end crosstalk) | 1 MHz | ≤dB | |
4 MHz | ≤dB | ||
8 MHz | ≤dB | ||
10 MHz | ≤dB | ||
16 MHz | ≤dB | ||
20 MHz | ≤dB | ||
25 MHz | ≤dB | ||
31.25 MHz | ≤dB | ||
62.5 MHz | ≤dB | ||
100 MHz | ≤dB | ||
200 MHz | ≤dB | ||
250 MHz | ≤dB | ||
PSNEXT (power sum near-end crosstalk) | 1 MHz | ≥dB | |
4 MHz | ≥dB | ||
8 MHz | ≥dB | ||
10 MHz | ≥dB | ||
16 MHz | ≥dB | ||
20 MHz | ≥dB | ||
25 MHz | ≥dB | ||
31.25 MHz | ≥dB | ||
62.5 MHz | ≥dB | ||
100 MHz | ≥dB | ||
200 MHz | ≥dB | ||
250 MHz | ≥dB | ||
ELFEXT | 1 MHz | ≥dB | |
4 MHz | ≥dB | ||
8 MHz | ≥dB | ||
10 MHz | ≥dB | ||
16 MHz | ≥dB | ||
20 MHz | ≥dB | ||
25 MHz | ≥dB | ||
31.25 MHz | ≥dB | ||
62.5 MHz | ≥dB | ||
100 MHz | ≥dB | ||
200 MHz | ≥dB | ||
250 MHz | ≥dB | ||
PSELFEXT (power sum far-end crosstalk) | 1 MHz | ≥dB | |
4 MHz | ≥dB | ||
8 MHz | ≥dB | ||
10 MHz | ≥dB | ||
16 MHz | ≥dB | ||
20 MHz | ≥dB | ||
25 MHz | ≥dB | ||
31.25 MHz | ≥dB | ||
62.5 MHz | ≥dB | ||
100 MHz | ≥dB | ||
200 MHz | ≥dB | ||
250 MHz | ≥dB | ||
Mechanické vlastnosti | |||
Provozní teplota | °C | -20...+70 | |
Teplota pokládky | °C | 0...+50 | |
Minimum bending radius for indoor installation | Diameter | >8 | |
Balení | |||
Spool | Diameter | mm | 380 |
Šířka | mm | 385 | |
průměr otvoru uvnitř cívky | mm | 33 |
Videa
How to attach RJ-45 connector to cat 5 UTP cable. Male RJ-45 connector J2008 (8P8C category 5e for UTP/FTP cables with solid wires) used for computer network cables. NETSET BOX UTP CAT 5e E1408 cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs). Crimping Tool HT-210N J9210 for RJ-45 plugs. Cable Tester (RJ-45, RJ-11) N7055 helps installers to build LAN systems and service existing networks. It tests cable continuity, detects shorts circuits and incorrect connections. The device can be used for UTP/FTP cables terminated with RJ-45 connectors or for telephone cables terminated with RJ-11 phone plugs.