Kabel NETSET U/UTP kategorii 6 B2ca-s1a-d1-a1 /500m/

Kód zboží: E1615_500
10376,96 Kč
Cena s DPH Sleva Množství platnost
10376,96 Kč 0 % od 1 ks.
od 0,00 Kč
Dostupný

Záruka

Záruka - 15 let.

Podrobný popis

The NETSET BOX U/UTP cat 6 cable far exceeds the requirements for Category 6 twisted pair cables.
NETSET cables are compliant with the Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables for use in construction works.
The requirements for using cables with a specific reaction to fire class in a given type of building should be based on a risk analysis made by the installation designer or other national formal and legal documents. The CPR Directive does not impose on the EU Member States the requirements for types of buildings and associated cables with specific fire reaction classes.
According to guidelines of the Association of Polish Electrical Engineers guidelines, CPR class B2ca cable must be installed in escape routes:
  • High-rise buildings (WW) with a height of more than 55 m above ground level
  • High-rise buildings (W) with a height of more than 25 m to 55 m above ground level or residential buildings with the number of floors above ground level from 9 to 18 inclusive
  • Buildings in human risk category ZL I with rooms intended for simultaneous presence of more than 50 people who are not permanent users, and not intended primarily for use by people with reduced mobility
  • Buildings in human risk category ZL II – intended primarily for use by people with reduced mobility, such as hospitals, nurseries, kindergartens, nursing homes
  • Buildings in human risk category ZL III – commercial buildings not classified unser ZL I and ZL II
  • Buildings in human risk category ZL IV – residential
  • Buildings in human risk category ZL V – collective residence not classified under ZL I and ZL II
  • PM and IN buildings (production buildings, warehouses, livestock etc.).
Thanks to the fulfillment of such high criteria, the twisted pair can be used in buildings and their parts that have increased fire resistance requirements, e.g. in corridors, staircases or escape routes.
The NETSET BOX U/UTP CAT 6 E1614 cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs).
The NETSET cable comes from the latest generation of UTP twisted pair cables. Its external diameter has been reduced to 5.9 mm, which considerably facilitates insertion of the cable into ducts and pipes. Special insulation material makes it easier to attach RJ-45 connectors.
Distinguishing features of the NETSET BOX U/UTP CAT 6 cable:
  • top quality materials, made to tight specifications, proven with a, 15-year quality guarantee,
  • flammability class B2ca-s1a-d1-a1
  • preliminary quality control of materials and thorough tests of the finished product,
  • meter markers,
  • cooper solid wires diameter 0.565 mm,
  • insulation of conductors made of insulating, mass-coloured HDPE, conductor diameter: 0.98 mm, insulation colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
  • cable sheath made of LSZH compliant material, outer diameter 6.4 mm,
  • length marker print error max. 0.5%
The NETSET U/FTP cat. 6 E1615 twisted pair cable has been manufactured in accordance with the standards:
EN50575:2014, EN60332-1-2:2004, EN50399:2011, EN60754-2:2014, EN 13501-6:2014.
The cable comes with a 15-year warranty.
The manufacturer guarantees the stability of parameters for at least 15 years, on the condition that the cable is packed, transported, installed, and used according to adequate European standards (among others E-79100 and EN 50174-1), within the permissible environmental conditions.
The NETSET NETSET U/FTP Category 6 E1615 twisted pair cable is intended for use in an environment with temperature from -20oC to +50 oC. Installation temperature not lower than 0oC and not higher than +50oC. The bending radius should not be less than 8 times the outside diameter.
Test results
  • Return Loss
Frequency [MHz] Result (min.) [dB]
1 20.0
4 23.0
8 24.5
10 25.0
16 25.0
20 25.0
25 24.3
31.25 23.6
62.5 21.5
100 20.1
200 18
250 17.3
  • Attenuation
Frequency [MHz] Result (min.) [dB]
1 2,03
4 3,78
8 5,32
10 5,95
16 8,47
25 9,51
31,25 10,67
62,5 15,38
100 19,8
200 28,98
250 32,85
  • NEXT (near end crosstalk)
Frequency [MHz] Result (min.) [dB]
1 74.3
4 65.3
8 60.8
10 59.3
16 56.2
20 54.8
25 53.3
31.25 51.9
62.5 47.7
100 44.3
200 39.8
250 38.3
  • PSNEXT (power sum near end crosstalk)
Frequency [MHz] Result (min.) [dB]
1 72,3
4 63,3
8 58,8
10 57,3
16 54,2
20 51,3
31,25 49,9
62,5 45,4
100 42,3
200 37,8
250 36,3
  • ELFEXT (equal level far end crosstalk loss testing)
Frequency [MHz] Result (min.) [dB]
1 67,8
4 55,8
8 49,7
10 47,8
16 43,7
20 41,8
25 39,8
31,25 37,9
62,5 31,9
100 27,8
200 21,8
250 19,8
  • PSELFEXT (power sum equal level far end crosstalk loss testing)
Frequency [MHz] Result (min.) [dB]
1 64.8
4 52.8
8 46.7
10 44.8
16 40.7
20 38.8
25 36.8
31.25 34.9
62.5 28.9
100 24.8
200 18.8
250 16.8
The parameters show that NETSET BOX U/UTP CAT 6 E1614 fulfills all requirements for Category 6 cables, with a large safety margin.

Specifikace

Název NETSET U/UTP cat. 6
Typ zboží
Výrobce Dipol
Značka NETSET
Typ kabelu U/UTP
Aplikace
Category 6
Délka kabelu m 500
CPR class B2ca s1a,d1,a1
Fyzikální vlastnosti
Žila Material Cooper
Průměr mm 0,55
Izolace vodiče Material HDPE (polyethylene)
Průměr mm 0,98
Kroucené páry colors white-brown/brown, white-blue/blue, white-orange/orange, white-green/green
Twisted pair shield Material Al/Mylar
plášť Průměr mm 6,4
thickness mm 0,75
Barva RAL7032 (gray)
No
Nosný kabel No
Rip-cord Ano
Drážkování No
Chyba tisku značky délky <0.5
Elektrické vlastnosti
Impedance Ω 100
Zpoždění zkreslení ns/100 m <45
Asymetrie kapacity ve vztahu k zemi pF/100m 330
Stejnosměrný odpor Ohm/100 m 9,38
Asymetrie odporu <5
Ztráty zpětného toku 1 MHz ≥dB 20
4 MHz ≥dB 23
8 MHz ≥dB 24,5
10 MHz ≥dB 25
16 MHz ≥dB 25
20 MHz ≥dB 25
25 MHz ≥dB 24,3
31.25 MHz ≥dB 23,6
62.5 MHz ≥dB 21,5
100 MHz ≥dB 20,1
200 MHz ≥dB 18
250 MHz ≥dB 17,3
Ztráty 1 MHz ≤dB 2
4 MHz ≤dB 3,78
8 MHz ≤dB 5,32
10 MHz ≤dB 5,95
16 MHz ≤dB 8,47
20 MHz ≤dB 9,3
25 MHz ≤dB 9,51
31.25 MHz ≤dB 10,67
62.5 MHz ≤dB 15,38
100 MHz ≤dB 19,8
200 MHz ≤dB 28,98
250 MHz ≤dB 32,85
NEXT (přeslech na blízkém konci) 1 MHz ≤dB 74,3
4 MHz ≤dB 65,3
8 MHz ≤dB 60,8
10 MHz ≤dB 59,3
16 MHz ≤dB 56,2
20 MHz ≤dB 54,8
25 MHz ≤dB 53,3
31.25 MHz ≤dB 51,9
62.5 MHz ≤dB 47,7
100 MHz ≤dB 44,3
200 MHz ≤dB 39,8
250 MHz ≤dB 38,3
PSNEXT (součet výkonových přeslechů na blízkém konci) 1 MHz ≥dB 72,3
4 MHz ≥dB 63,3
8 MHz ≥dB 58,8
10 MHz ≥dB 57,3
16 MHz ≥dB 54,2
20 MHz ≥dB 52,8
25 MHz ≥dB 51,3
31.25 MHz ≥dB 49,9
62.5 MHz ≥dB 45,4
100 MHz ≥dB 42,3
200 MHz ≥dB 37,8
250 MHz ≥dB 36,3
ELFEXT 1 MHz ≥dB 67,8
4 MHz ≥dB 55,8
8 MHz ≥dB 49,7
10 MHz ≥dB 47,8
16 MHz ≥dB 43,7
20 MHz ≥dB 41,8
25 MHz ≥dB 39,8
31.25 MHz ≥dB 37,9
62.5 MHz ≥dB 31,9
100 MHz ≥dB 27,8
200 MHz ≥dB 21,8
250 MHz ≥dB 19,8
PSELFEXT (součet výkonových přeslechů na vzdáleném konci) 1 MHz ≥dB 64,8
4 MHz ≥dB 52,8
8 MHz ≥dB 46,7
10 MHz ≥dB 44,8
16 MHz ≥dB 40,7
20 MHz ≥dB 38,8
25 MHz ≥dB 36,8
31.25 MHz ≥dB 34,9
62.5 MHz ≥dB 28,9
100 MHz ≥dB 24,8
200 MHz ≥dB 18,8
250 MHz ≥dB 16,8
Mechanické vlastnosti
Provozní teplota °C -20...+70
Teplota pokládky °C 0...+50
Minimální poloměr ohybu pro vnitřní instalaci Průměr >8
Balení
Spool Průměr mm 380
Šířka mm 385
průměr otvoru uvnitř cívky mm 33

Videa

Krimpování konektoru RJ-45 na UTP kabel kategorie 6

A short instructional video on crimping RJ-45 connector on a category 6 UTP cable, according to the EIA/EIA 568B standard. The items used: NETSET U/UTP cat. 6 cable, 8-pin RJ-45 modular plug, modular plug boot, HT-210N crimping tool, cable tester NS-468AT.

RJ45 plug on UTP cable - Installing

How to attach RJ-45 connector to cat 5 UTP cable. Male RJ-45 connector J2008 (8P8C category 5e for UTP/FTP cables with solid wires) used for computer network cables. NETSET BOX UTP CAT 5e E1408 cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs). Crimping Tool HT-210N J9210 for RJ-45 plugs. Cable Tester (RJ-45, RJ-11) N7055 helps installers to build LAN systems and service existing networks. It tests cable continuity, detects shorts circuits and incorrect connections. The device can be used for UTP/FTP cables terminated with RJ-45 connectors or for telephone cables terminated with RJ-11 phone plugs.