12057,41 Kč
Cena s DPH | Sleva | Množství | platnost |
---|---|---|---|
12057,41 Kč | 0 % | od 1 ks. |
Dostupný
Podrobný popis
NETSET cables are compliant with the Construction Products Regulation (CPR) and EN 50575 harmonized European standard that specifies reaction to fire performance requirements, test and assessment methods for electric cables used for the supply of electricity and for control and communication purposes, which are intended for use in construction works and subject to performance requirements on reaction to fire.
The NETSET S/FTP 7 E1626 cable has been tested in a FORCE Certification Notified Body no. 0200 and awarded a Cca -s1a, d1, a1 fire performance rating.
The CAT 7 NETSET S/FTP shielded cable is a high-quality cable designed for professional indoor data transmission systems. Made of braid and foil, the shielding allows to minimize crosstalk and interference with the external environment.
- highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee,
- parameters far exceeding the requirements for Category 7 twisted pair cables
- preliminary quality control of raw materials and thorough tests of the final product,
- meter markers,
- solid wires, 0.56 mm in diameter (23 AWG),
- wire insulation made of skin-foam-skin PE; diameter: 0.56 mm; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
- insulated, screened wires twisted in pairs,
- sheath made of LSZH, 7.6 mm external diameter,
- meter markers - length error less than 0.5%.

1 - white-blue / blue wire
2 - white-brown / brown wire
3 - white-green / green wire
4 - white-orange / orange wire
5 - drain wire
6 - rip-cord
7 - aluminum screen
8 - sheath
9 - screening braid
2 - white-brown / brown wire
3 - white-green / green wire
4 - white-orange / orange wire
5 - drain wire
6 - rip-cord
7 - aluminum screen
8 - sheath
9 - screening braid
The CAT 7 NETSET S/FTP shielded cable is manufactured in compliance with the following standards:
- General cat.7 requirements
- ISO/IEC 11801:2011 (Ed. 2.2)
- IEC 61156-5:2012 (Ed. 2.1)
- EN 50173-1:2011
- EN 50173-2:2007 A1:2010
- EN 50288-10-1:2012
- ANSI/TIA-568-C.2:2009
- Fire performance
- Cca classification
- EN 50575:2014 including amendment A1:2016
The cable comes with a 15-year warranty.
The manufacturer guarantees the stability of parameters for at least 15 years, on the condition that the cable is packed, transported, installed, and used according to adequate European standards (among others E-79100 and EN 50174-1), within the permissible environmental conditions.
The CAT 7 NETSET S/FTP cable (E1626) is designed to work in temperatures from -20 oC to +50 oC, and can be installed between 0 oC and +50 oC. The bend radius should be equal or greater than 8 times the external diameter.
Test results
- Return Loss
Frequency [MHz] | Result [>dB] |
1 | 20 |
4 | 23 |
8 | 24.5 |
10 | 25 |
16 | 25 |
20 | 25 |
25 | 24.3 |
31.25 | 23.6 |
62.5 | 21.5 |
100 | 20.1 |
200 | 18 |
250 | 17.3 |
300 | 17.3 |
600 | 17.3 |
- Attenuation
Frequency [MHz] | Result [dB/100m] |
1 | - |
4 | 3.74 |
8 | 5.24 |
10 | 5.86 |
16 | 7.41 |
20 | 8.29 |
25 | 9.29 |
31.25 | 10.41 |
62.5 | 14.88 |
100 | 19.02 |
200 | 27.47 |
250 | 30.97 |
300 | 34.19 |
600 | 50.10 |
- NEXT
Frequency[MHz] | Result [>dB] |
1 | 78 |
4 | 78 |
8 | 78 |
10 | 78 |
16 | 78 |
20 | 78 |
25 | 78 |
31.25 | 78 |
62.5 | 75.5 |
100 | 72.4 |
200 | 67.9 |
250 | 66.4 |
300 | 65.2 |
600 | 60.7 |
- PSNEXT
Frequency [MHz] | Result [>dB] |
1 | 75 |
4 | 75 |
8 | 75 |
10 | 75 |
16 | 75 |
20 | 75 |
25 | 75 |
31.25 | 75 |
62.5 | 72.5 |
100 | 69.4 |
200 | 64.9 |
250 | 63.4 |
300 | 62.2 |
600 | 57.7 |
- ELFEXT
Frequency [MHz] | Result [>dB] |
1 | 78 |
4 | 78 |
8 | 75.9 |
10 | 74 |
16 | 69.9 |
20 | 68 |
25 | 66 |
31.25 | 64.1 |
62.5 | 58.1 |
100 | 54 |
200 | 48 |
250 | 46 |
300 | 44.5 |
600 | 38.4 |
- PSELFEXT
Frequency [MHz] | Result [>dB] |
1 | 75 |
4 | 75 |
8 | 72.9 |
10 | 71 |
16 | 66.9 |
20 | 65 |
25 | 63 |
31.25 | 61.1 |
62.5 | 55.1 |
100 | 51 |
200 | 45 |
250 | 43 |
300 | 41.5 |
600 | 35.4 |
Specifikace
Název | NETSET S/FTP cat. 7 | ||
Typ zboží | |||
Výrobce | |||
Značka | NETSET | ||
Typ kabelu | S/FTP | ||
Aplikace | |||
Category | 7 | ||
Délka kabelu | m | 500 | |
CPR class | Cca-s1a,d1,a1 | ||
Fyzikální vlastnosti | |||
Žila | Material | Cooper | |
Žila | Průměr | mm | 0,560 |
Izolace vodiče | Material | PE | |
Izolace vodiče | Průměr | mm | 1,33 |
Kroucené páry | colors | white-brown/brown, white-blue/blue, white-orange/orange, white-green/green | |
Twisted pair shield | Material | Al/Mylar | |
Conductor shield | Material | Al/Mylar | |
plášť | Průměr | mm | 7,6 |
thickness | mm | 0,55 | |
Barva | RAL7032 (gray) | ||
No | |||
Nosný kabel | No | ||
Rip-cord | Ano | ||
Drážkování | No | ||
Chyba tisku značky délky | <0.5 | ||
Elektrické vlastnosti | |||
Impedance | Ω | 100 | |
Rychlost šíření NVP | 74 | ||
Zpoždění zkreslení | ns/100 m | <45 | |
Asymetrie kapacity ve vztahu k zemi | pF/100m | 330 | |
Stejnosměrný odpor | Ohm/100 m | 9,38 | |
Asymetrie odporu | <2 | ||
Ztráty zpětného toku | 1 MHz | ≥dB | 20 |
Ztráty zpětného toku | 4 MHz | ≥dB | 23 |
8 MHz | ≥dB | 24,5 | |
10 MHz | ≥dB | 25 | |
16 MHz | ≥dB | 25 | |
20 MHz | ≥dB | 25 | |
25 MHz | ≥dB | 24,3 | |
31.25 MHz | ≥dB | 23,6 | |
62.5 MHz | ≥dB | 21,5 | |
100 MHz | ≥dB | 20,1 | |
200 MHz | ≥dB | 18 | |
250 MHz | ≥dB | 17,3 | |
300 MHz | ≥dB | 17,3 | |
600 MHz | ≥dB | 17,3 | |
Ztráty | 4 MHz | ≤dB | 3,78 |
8 MHz | ≤dB | 5,24 | |
10 MHz | ≤dB | 5,86 | |
16 MHz | ≤dB | 7,41 | |
20 MHz | ≤dB | 8,29 | |
25 MHz | ≤dB | 9,29 | |
31.25 MHz | ≤dB | 10,41 | |
62.5 MHz | ≤dB | 14,88 | |
100 MHz | ≤dB | 19,02 | |
200 MHz | ≤dB | 27,47 | |
250 MHz | ≤dB | 30,97 | |
300 MHz | ≤dB | 34,19 | |
600 MHz | ≤dB | 50,1 | |
NEXT (přeslech na blízkém konci) | 1 MHz | ≤dB | 78 |
NEXT (přeslech na blízkém konci) | 4 MHz | ≤dB | 78 |
8 MHz | ≤dB | 78 | |
10 MHz | ≤dB | 78 | |
16 MHz | ≤dB | 78 | |
20 MHz | ≤dB | 78 | |
25 MHz | ≤dB | 78 | |
31.25 MHz | ≤dB | 78 | |
62.5 MHz | ≤dB | 75,5 | |
100 MHz | ≤dB | 72,4 | |
200 MHz | ≤dB | 67,9 | |
250 MHz | ≤dB | 66,4 | |
300 MHz | ≤dB | 65,2 | |
600 MHz | ≤dB | 60,7 | |
PSNEXT (součet výkonových přeslechů na blízkém konci) | 1 MHz | ≥dB | 75 |
PSNEXT (součet výkonových přeslechů na blízkém konci) | 4 MHz | ≥dB | 75 |
8 MHz | ≥dB | 75 | |
10 MHz | ≥dB | 75 | |
16 MHz | ≥dB | 75 | |
20 MHz | ≥dB | 75 | |
25 MHz | ≥dB | 75 | |
31.25 MHz | ≥dB | 75 | |
62.5 MHz | ≥dB | 72,5 | |
100 MHz | ≥dB | 69,4 | |
200 MHz | ≥dB | 64,9 | |
250 MHz | ≥dB | 63,4 | |
300 MHz | ≥dB | 62,2 | |
600 MHz | ≥dB | 57,7 | |
ELFEXT | 1 MHz | ≥dB | 78 |
ELFEXT | 4 MHz | ≥dB | 78 |
8 MHz | ≥dB | 75,9 | |
10 MHz | ≥dB | 74 | |
16 MHz | ≥dB | 69,9 | |
20 MHz | ≥dB | 68 | |
31.25 MHz | ≥dB | 64,1 | |
62.5 MHz | ≥dB | 58,1 | |
100 MHz | ≥dB | 54 | |
200 MHz | ≥dB | 48 | |
250 MHz | ≥dB | 46 | |
300 MHz | ≥dB | 44,5 | |
600 MHz | ≥dB | 38,4 | |
PSELFEXT (součet výkonových přeslechů na vzdáleném konci) | 1 MHz | ≥dB | 75 |
PSELFEXT (součet výkonových přeslechů na vzdáleném konci) | 4 MHz | ≥dB | 75 |
8 MHz | ≥dB | 72,9 | |
10 MHz | ≥dB | 71 | |
16 MHz | ≥dB | 66,9 | |
20 MHz | ≥dB | 65 | |
25 MHz | ≥dB | 63 | |
31.25 MHz | ≥dB | 61,1 | |
62.5 MHz | ≥dB | 55,1 | |
100 MHz | ≥dB | 51 | |
200 MHz | ≥dB | 45 | |
250 MHz | ≥dB | 43 | |
300 MHz | ≥dB | 41,5 | |
600 MHz | ≥dB | 35,4 | |
Mechanické vlastnosti | |||
Provozní teplota | °C | -20...+70 | |
Teplota pokládky | °C | 0...+50 | |
Minimální poloměr ohybu pro vnitřní instalaci | Průměr | >8 | |
Balení | |||
Spool | Průměr | mm | 380 |
Spool | Šířka | mm | 385 |
Weight | kg | 29 | |
průměr otvoru uvnitř cívky | mm | 33 |